919 – Diagnostic performance of a digital breast tomosynthesis–based imaging pathway in a peruvian dense-breast population

Authors

  • Gaston Wilmer Mendoza de Lama Detecta Clínica – Peru.
  • Nancy Elena Muñoz Quispe Detecta Clínica – Peru.
  • Diana Diaz -Llontop Detecta Clínica – Peru.
  • Richard Eduardo Castillo Laborio Detecta Clínica – Peru.

DOI:

https://doi.org/10.29289/25945394V36S10919

Keywords:

breast neoplasms, mammography, tomosynthesis

Abstract

Breast density varies across populations and tends to be higher in Latin American women, potentially affecting the performance of breast imaging modalities. However, real-world evidence on digital breast tomosynthesis (DBT) — based
diagnostic pathways in these settings remains limited. This study aimed to evaluate the diagnostic performance of a DBTbased imaging approach within a Peruvian population, focusing on recall resolution with ultrasound, biopsy yield, cancer
detection rate (CDR), and predictors of malignancy in a predominantly dense-breast cohort. A retrospective analysis was
conducted on 2,690 DBT examinations performed at a tertiary breast imaging center in Peru, excluding BI-RADS 6 cases.
Examinations classified as BI-RADS 0 underwent targeted ultrasound, and biopsies were indicated for BI-RADS ≥4 identified through mammography or ultrasound. Key outcomes included recall rate, biopsy rate, positive predictive value of
biopsy recommendation (PPV3), and CDR. Multivariable logistic regression was used to identify independent predictors
of malignancy among biopsied patients. Dense breasts were observed in 65.7% of cases. The recall rate was 45.0%. Among
BI-RADS 0 cases, 87.9% were resolved via ultrasound without requiring a biopsy, while 12.0% were upgraded to biopsy.
A total of 98 biopsies were performed, with 66 malignancies detected, resulting in a PPV3 of 67.3%. The overall CDR was
24.5 cancers per 1,000 examinations. Higher BI-RADS categories (≥4B vs. 4A) were independently associated with malignancy, while age showed a non-significant trend. Breast density, family history, and imaging indication were not independent predictors after adjustment. In conclusion, despite high recall rates, the DBT-based pathway demonstrated strong
diagnostic performance. Targeted ultrasound effectively optimized patient triage, maintaining high biopsy yield and
cancer detection. These findings support the use of tailored DBT-based strategies in Latin American populations with a
high breast density.