Accuracy of stereotactic vaccum-assisted breast biopsy for investigating suspicious calcifications in 2,021 patients at a public hospital in Brazil

Authors

  • Andressa Amorim Pérola Byington Hospital – Women’s Reference Center – São Paulo (SP), Brazil.
  • Andre Mattar Pérola Byington Hospital – Women’s Reference Center – São Paulo (SP), Brazil.
  • Marina Diógenes Teixeira Pérola Byington Hospital – Women’s Reference Center – São Paulo (SP), Brazil.
  • Marcellus do Nascimento Moreira Ramos Pérola Byington Hospital – Women’s Reference Center – São Paulo (SP), Brazil.
  • Marcelo Antonini Instituto de Assistência Médica ao Servidor Público Estadual – São Paulo (SP), Brazil.
  • Luciana Lamarão Damous Instituto de Assistência Médica ao Servidor Público Estadual – São Paulo (SP), Brazil.
  • Reginaldo Guedes Coelho Lopes Instituto de Assistência Médica ao Servidor Público Estadual – São Paulo (SP), Brazil.
  • Luiz Henrique Gebrim Pérola Byington Hospital – Women’s Reference Center – São Paulo (SP), Brazil.

DOI:

https://doi.org/10.29289/259453942023V33S1019

Keywords:

breast cancer, diagnosis

Abstract

Objective: The objective of this study was to evaluate the accuracy of vacuum-assisted stereotactic biopsy (VASB) in
the investigation of nonpalpable suspicious calcifications. Methodology: It was a retrospective study from July 2012 to
December 2020, in which 2,021 women with suspicious calcifications detected on mammography (BI-RADS 4 and 5) had
VASB performed at Hospital Estadual Pérola Byington, São Paulo, Brazil. Fragments were obtained and sent to an anatomopathological study; a metal clip was placed on the biopsy site. Four groups were analyzed, based on the biopsy results:
benign, precursor lesions, ductal carcinoma in situ (DCIS), and invasive ductal carcinoma (ICD). Results: The median
age of patients was 55 years (49–63 years). Pathology results on VASB were classified, respectively, as benign n=1,340
(66.3%), precursor lesions n=84 (4.1%), DCIS n=441 (21.8%), and ICD n=156 (7.7%). In the 60 patients whose VASB results
were benign because of anatomopathological disagreement, surgery was performed. The following results were obtained:
benign n=30 (50%), ICD and DCIS n=21 (35%), and precursor lesions n=9 (15%). The sensitivity of the method was 91.7%,
specificity was 97.1%, false negative rate was 3%, positive predictive value was 92.4%, and negative predictive value was
96.9%. Conclusion: The VASB method has good accuracy in distinguishing lower and higher-risk lesion groups compared
with the gold standard. It has high predictive value in both benign and malignant lesions, guiding therapeutic planning.

Downloads

Download data is not yet available.

Downloads

Published

2026-03-12

How to Cite

Amorim, A., Mattar, A., Teixeira, M. D., Ramos, M. do N. M., Antonini, M., Damous, L. L., … Gebrim, L. H. (2026). Accuracy of stereotactic vaccum-assisted breast biopsy for investigating suspicious calcifications in 2,021 patients at a public hospital in Brazil. Mastology, 33(suppl.1). https://doi.org/10.29289/259453942023V33S1019