Development and validation of the axillary web syndrome classification scale

Authors

  • Nayara Alves de Freitas Lemos Universidade Federal de Goiás, Hospital das Clínicas, Centro Avançado de Diagnóstico da Mama (CORA), Rede Brasileira de Pesquisa em Câncer de Mama – Goiânia (GO), Brazil.
  • Karla Ferreira do Carmo Universidade Paulista – São Paulo (SP), Brazil.
  • Leonardo Ribeiro Soares Universidade Federal de Goiás, Hospital das Clínicas, Centro Avançado de Diagnóstico da Mama (CORA), Rede Brasileira de Pesquisa em Câncer de Mama – Goiânia (GO), Brazil.
  • Ruffo Freitas-Junior Universidade Federal de Goiás, Hospital das Clínicas, Centro Avançado de Diagnóstico da Mama (CORA), Rede Brasileira de Pesquisa em Câncer de Mama – Goiânia (GO), Brazil.

DOI:

https://doi.org/10.29289/259453942025V35S1069

Keywords:

physical therapy services, sentinel lymph node biopsy, fibrosis, validation study, lymphatic system

Abstract

  • Objective: To develop and validate a clinical scale for the classification of axillary web syndrome (EC-SRA). Methods: This
    is an exploratory, methodological development research with a quantitative approach. The study included 23 women
    undergoing surgical treatment for breast cancer who received axillary approaches and were treated at the physiotherapy
    outpatient clinic of the Mastology Service of Hospital das Clínicas (Cora/HC), and signed the informed consent form.
    Women with alterations or impairment of the shoulder ipsilateral to the breast operated prior to surgical treatment were
    excluded. The methodology for constructing the instrument was divided into stages: 1. Establishment of the conceptual
    structure; 2. Construction and structuring of EC-SRA items; 3. Content validation (by seven experts); 4. Assessment of
    usability and refinement of the instrument; and 5. Analysis of results. The research was conducted between April 2020 and
    August 2021. Results: The calculated content validity index was 0.97, indicating a high level of agreement among experts,
    since values of at least 0.80 are considered acceptable. The reliability of the instrument, verified through internal consistency measured by calculating Cronbach’s alpha among evaluators, was 0.8, a value considered ideal. The overall internal
    consistency of the instrument was considered satisfactory. The analysis of agreement of the instrument measured by the
    evaluators showed a general correlation coefficient of 0.986, with a p<0.001. Conclusion: Based on the usability assessment, it is possible to conclude that the EC-SRA is capable of measuring the cord and reproducing consistent, stable, and
    accurate results, presenting reliability. The EC-SRA, therefore, has the potential to be widely used and avoid the merely
    subjective assessment of the SRA, which is the current clinical reality.